Primary Antibodies

Series of primary antibodies available (CD markers, beta amyloids, bromodeoxyuridine, breast tumor antigen, Carcinoma Associated Mucin Antigen, Colon Antigen, Cytomegalovirus, estrogen receptors, endothelial growth factors, desmin, tumour marker, Glial Fibrillary Acidic Protein, Granular Membrane Protein, homing receptor, Chorionic Gonadotropins, Hominng Receptor, ICAM-1, Integrins, Interleukin-2 Receptor, L26, L-selectin, LECAM-1, Leukocyte Common Antigen, macrophage marker, Monocytes, Natural Killer Cells, NK cells, Ovarian Cancer Marker, Parathyroid Hormone, Pappillomavirus (HPV), Platelet, Progesterone Receptor, Reed Stemberg Cells, Secretin, Testosterone, Transferrin Receptor, Tumor Necrosis Factor, Ubiquitin, etc.
 
Negetive Control Sera

Negative control sera and isotype controls are employed in place of primary antibody for staining negative control slides.
Innovex Biosciences offers a wide selection of negative control sera and isotype controls for different sources of primary antibodies employed.

 
Stat Staining System

Kit system used for animal and human tissue staining. These stains are used in Immunohistochemistry for immunohistochemical staining used in diagnosis and treatment of cancer. STAT-Q Multivalent Linking antibodies are also available for staining both MOUSE & RABBIT primary antibodies.

UNIQUE FEATURES:

  • No serum or protein blocking required
  • Total staining time of only 40 minutes for paraffin sections (from primary to mounted slides).
  • Total staining time of 15-20 minutes for frozen sections
  • Wash Free, one 5 second rinse in between incubation steps
  • No Avidin blocking required
  • Short 10 minute incubation steps
  • Highly amplified, cuts incubation time of 30 minute primaries to 10 minutes
  • Allows at least 2 fold increase in dilutions of current primary antibodies at 10 minute incubation time
  • No re-titration of current primary antibody titer is required, simply switch to STAT-Q staining system
  • Economical: Average cost per slide 65 cents
  • 3 years of shelf life

     
    Histo Stat Staining System

    One step better than stat staining system. Non-Biotin & Non-strepavidin system developed for Wash Free, Background Free, Pre-treatment Free immunostaining in 50 minutes. It takes lesser time and reactions steps for staining as compared to stat system. Applications are similar, used for immunohistochemical staining.
     
    Background Buster

    One of the main difficulties with IHC staining is overcoming specific or non-specific background. Optimization of fixation methods and times, pre-treatment with blocking agents, incubating antibodies with high salt, and optimizing post-antibody wash buffers and wash times are all important for obtaining high quality immunostaining. In addition, the presence of positive controls and negative controls for staining are essential for determining specificity.

    Background staining can be prevented by the use of INNOVEX Recombinant Protein Technology, Background Buster. Background Buster is also applicable to eliminating non-specific binding in immunofluorescence, ELISA and flow cytometric assays.
     
    Fc Receptor Blocker

    Innovex Fc Receptor Block is a peerless technology developed for eliminating non-specific staining caused by Fc receptors staining of lymphoid and hematopoietic cells. Eliminates false positive staining of white blood cells, lymphoid tissues, cytosmears (blood & bone marrow), must for CD marker staining and kappa.lambda staining

    ADVANCED and UNIQUE FEATURES :

  • 20 minute incubation step at room temperature
  • Eliminates false positive staining of white blood cells, lymphoid tissues, cytosmears (blood & bone marrow)
  • Insures accurate lymphoma and leukemia typing
  • Eliminates negative control staining of lymphomas, lymphoid tissues, and blood and bone marrow smears
  • Eliminates false positive staining for Kappa and Lambda staining
  • Eliminates false positive staining of Reed Sternberg cells
  • A must for CD markers staining in immunohistochemistry, immunofluorescence
  • A must for CD phenotyping via flow cytometry
  • A must for Immunoglobulins (Igs) staining via immunohistochemistry, flow cytometry and immunofluorescence
  • A must for kappa and lambda staining


     
    Signal Enhancers And Wash Buffers

    used with stat and histo-stat system. Specimens can be rinsed with these wash buffers prior to employing primary antibodies, also used for washing Elisa plates.
     
    Turbo Substrate/ Chromogen

    Chromogens is regarded as pigmented or pigment generating organ, organelle or microorganism. Liquid generating AEC and DaB systems for staining of chromogens.A biotinylated secondary antibody is coupled with streptavidin-horseradish peroxidase enzyme. This is reacted with 3,3'-Diaminobenzidine (DAB) to produce a brown staining wherever primary and secondary antibodies are attached in a process known as DAB staining.

     
    Chromogen Enhancer

    Innovex Biosciences Chromogen Enhancers are peerless technologies developed for intensifying chromogenic stains. Innovex Chromogen Enhancers amplify staining signals and minimize false negative staining.
     
    Permanent Mounting Media

    permanent mounting of immunostains and special stains from water. Permanently preserves AEC, DAB, Fast Red and other immuno stains.
    H&E system haematoxylin and eosin stain is a popular staining method in histology. It is the most widely used stain in medical diagnosis; for example when a pathologist looks at a biopsy of a suspected cancer, the histological section is likely to be stained with H&E. “H&E Mount” is a unique, permanent mounting media designed for H&E stains from water or alcohol H&E stained slides mounted with “H&E Mount” do not display any loss of eosin or hematoxylin staining that is often observed when H&E slides are mounted from xylene.

    Probe Mount Probe Mount is a permanent mounting media formulated for mounting and preserving immunofluorescence and in-situ stains counterstained with Nuclear Fast Red and also for Special Stain. Counterstaining with Nuclear-Fast Red is commonly practiced when staining for DNA or RNA probes for contrasted viewing. Mounting of specimens counterstained or stained with Nuclear Fast Red require mounting with PROBE MOUNT.
     
    Support Reagents

    Innovex unique non-citrate formulation with built-in pH stabilizer for optimal and gentle unmasking of antigens from formalin fixed sections by high heat method.

    Cyto-Q Immunodillutent and Block Antibodies diluted in Cyto-Q, simply dilute and refrigerate it stabilizes antibodies also block their active sites.

    Isotonic buffers available for all activities.
     
    Stat Counterstains

    A counterstain is a stain with color contrasting to the principal stain, making the stained structure more easily visible. Ex. H&E stain.

    Innovex offers nuclear counterstains, cytoplasmic counterstains.
     
     
     
         
     
       
     