TYD02-10 Laboratory Syringe Pump
Product introduction
It can assemble ten syringes, other quantity can be customized;Good performance, high precision and high accuracy;Durable mechanical transmission design, long life and good reliability.Support for multiple working mode;High resolution color touch screen LCD, simple and easy to set parameters, status display intuitive and clear;With adjustable protection agencies and alarm mechanism;The RS – 485 communication, support the MODBUS protocol, easy to connect to other devices;All stainless steel shell, easy to clean and maintain.
Flow: 0.184nL/min-24.520ml/min
Max: 10 Channels
Function and Feature
• It can assemble ten syringes;
• A variety of working mode choice;
• Color touch screen, LCD display, convenient and quick operation;
• Support screen lock, key mute operation;
• With lights, buttons, clearly working state;
• Support a variety of standard syringe, customize syringe;
• High precision control;
• Syringe protection and traffic jam alarm;
• RS485 communication, support the MODBUS protocol;
• External signal control start-stop and direction;
• A wide range of power input;
• Full metal shell.
Model selection(Flow rate =Linear rate×Syringe inner sectional area)
Syringe size | Syringe ID(mm) | Min. flow rate (nl/min) | Max .flow rate(ml/min) |
10μl | 0.485 | 0.184 | 0.027 |
25μl | 0.729 | 0.417 | 0.626 |
50μl | 1.03 | 0.833 | 0.125 |
100μl | 1.457 | 1.667 | 0.250 |
250μl | 2.304 | 4.169 | 0.625 |
500μl | 3.256 | 8.326 | 1.248 |
1ml | 4.699 | 17.342 | 2.601 |
5ml | 11.989 | 112.890 | 16.933 |
10ml | 14.427 | 163.469 | 24.520 |
Syringe size: 10 ul – 10 ml;
• Work mode: infusion, withdraw, infusion/withdraw, withdraw/infusion, continuous mode;
• Channel number: 10;
• Stroke of pump: 140 mm;
• pusher advance per microstep: 0.156 um/ustep;
• linear speed: 1 um/min – 150 um/min;
• Linear resolution: 1 um/min;
• Linear travel accuracy: error <± 0.35% (?30% of pump stroke);
• Linear force: maximum rated: > 20 KGF;
• Thrust regulation: 1-100% arbitrary adjustable.
• Syringe selection: built-in main manufacturers, the main model syringe to choose;Can use custom syringe, direct input syringe size& diameter;
• Flow calibration: through the calibration procedure to obtain more accurate fluid volume;
• Display: 4.3 -inch color LCD, 480 * 272 resolution, color 65 k;With screen display and transfusion volume, quantity of liquid, flow, operation direction, syringe specification, etc.;Animation display operation status;
• Operation mode: touch screen + button;
• Power-off memory: storing the running parameters automatically.;
• Other features: pause and stop;The sound tip;The lock parameters;Fast forward and retreat quickly;
• State signal output: 1 road stop state, 1 state road direction;
• Control signal input: 1 way down along the priming, 1 way down along the trigger to stop;
• communication interface: RS485, MODBUS protocol;
• Applicable power: AC90-264 – v / 20 w;
• working temperature: 5 to 40 ?;
• Relative humidity: < 80% RH;
• Dimension: 290 * 280 *175 mm
• Weight: 5.2 kg